Effect of High-Dose Drug-Coated Balloon Repetition After Drug-Coated Balloon Failure

J Endovasc Ther. 2023 Nov 26:15266028231214167. doi: 10.1177/15266028231214167. Online ahead of print.

Abstract

Purpose: Although the optimal treatment for femoropopliteal (FP) drug-coated balloon (DCB) restenosis lesions remains debatable, the effectiveness of DCB repetition for DCB restenosis has been reported. However, the optimal DCB repetition strategy is not yet established. Thus, this study aimed to compare the clinical outcomes of high-dose DCB repetition with those of low-dose DCB repetition for FP DCB restenosis lesions.

Materials and methods: This single-center, observational study used a clinical database of 677 consecutive patients undergoing FP endovascular intervention for symptomatic peripheral artery disease between December 2018 and December 2021. Of these patients, 89 cases treated with DCB repetition for FP DCB restenosis lesions were analyzed. The primary endpoint was recurrent restenosis (re-restenosis) and the secondary endpoints were recurrent target-lesion revascularization (TLR), re-occlusion, and major adverse limb events (MALE) obtained using propensity score matching. Interaction analysis was also performed to explore the effects of the baseline characteristics on the association between high- and low-dose DCB with restenosis risk.

Results: After propensity score matching, high-dose DCB demonstrated a significantly higher freedom from re-restenosis compared with low-dose DCB repetition at 1 year (90.4% vs 40.9%, p=0.034). In addition, freedom from re-TLR and MALE at 1 year was significantly higher in the high-dose DCB group (95.0% vs 53.3%, p=0.025; 95.0% vs 54.7%, p=0.025, respectively). Conversely, freedom rates from re-occlusion were not significantly different between the 2 groups (100.0% vs 84.0%, p=0.99). No baseline characteristics or perioperative outcomes had any significant interaction effect on the association of high-dose DCB versus low-dose DCB with restenosis risk.

Conclusion: For FP DCB restenosis lesions, high-dose DCB repetition offered more favorable outcomes than low-dose DCB repetition.

Clinical impact: This study revealed that for femoropopliteal drug-coated balloon (DCB) restenosis lesions, high-dose DCB repetition obtained more favorable outcomes than low-dose DCB repetition. In addition, there was no significant interaction effect on the association of high- versus low-dose DCB with re-restenosis risk for the baseline characteristics and perioperative outcomes. This finding might be also a reason for choosing high-dose DCB repetition for FP DCB restenosis lesions in daily clinical practice.

Keywords: drug-coated balloon; peripheral artery disease; restenosis.