Improved Utilization of Serial Testing Without Increased Admissions after Implementation of High-Sensitivity Troponin I: a Controlled Retrospective Cohort Study

J Gen Intern Med. 2024 Apr;39(5):739-746. doi: 10.1007/s11606-023-08535-3. Epub 2023 Nov 22.

Abstract

Background: Guidelines recommend high-sensitivity cardiac troponin (hs-cTn) for diagnosis of myocardial infarction. Use of hs-cTn is increasing across the U.S., but questions remain regarding clinical and operational impact. Prior studies have had methodologic limitations and yielded conflicting results.

Objective: To evaluate the impact of transitioning from conventional cardiac troponin (cTn) to hs-cTn on test and resource utilization, operational efficiency, and patient safety.

Design: Retrospective cohort study in two New York City hospitals during the months before and after transition from conventional cTn to hs-cTn at Hospital 1. Hospital 2 served as a control.

Participants: Consecutive emergency department (ED) patients with at least one cTn test resulted.

Intervention: Multifaceted hs-cTn intervention bundle, including a 0/2-h diagnostic algorithm for non-ST-elevation myocardial infarction, an educational bundle, enhancements to the electronic medical record, and nursing interventions to facilitate timed sample collection.

Main measures: Primary outcomes included serial cTn test utilization, probability of hospital admission, ED length of stay (LOS), and among discharged patients, probability of ED revisit within 72 h resulting in hospital admission. Multivariable regression models adjusted for age, sex, temporal trends, and interhospital differences.

Key results: The intervention was associated with increased use of serial cTn testing (adjusted risk difference: 48 percentage points, 95% CI: 45-50, P < 0.001) and ED LOS (adjusted geometric mean difference: 50 min, 95% CI: 50-51, P < 0.001). There was no significant association between the intervention and probability of admission (adjusted relative risk [aRR]: 0.99, 95% CI: 0.89-1.1, P = 0.81) or probability of ED revisit within 72 h resulting in admission (aRR: 1.1, 95% CI: 0.44-2.9, P = 0.81).

Conclusions: Implementation of a hs-cTn intervention bundle was associated with an improvement in serial cTn testing, a neutral effect on probability of hospital admission, and a modest increase in ED LOS.

Keywords: admission; emergency department; high sensitivity cardiac troponin; length of stay; myocardial infarction; patient outcomes; test utilization.

Publication types

  • Multicenter Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Aged
  • Biomarkers / blood
  • Cohort Studies
  • Emergency Service, Hospital*
  • Female
  • Hospitalization
  • Humans
  • Male
  • Middle Aged
  • Myocardial Infarction / blood
  • Myocardial Infarction / diagnosis
  • Patient Admission / statistics & numerical data
  • Retrospective Studies
  • Troponin I* / blood

Substances

  • Troponin I
  • Biomarkers