Dose-volume comparisons of proton therapy for pencil beam scanning with and without multi-leaf collimator and passive scattering in patients with lung cancer

Med Dosim. 2024;49(1):13-18. doi: 10.1016/j.meddos.2023.10.006. Epub 2023 Nov 6.

Abstract

This study evaluated the dose distributions of proton pencil beam scanning (PBS) with/without a multileaf collimator (MLC) compared to passive scattering (PS) for stage I/II lung cancers. Collimated/uncollimated (PBS+/PBS-) and PS plans were created for 20 patients. Internal-clinical-target-volumes (ICTVs) and planning-target-volumes (PTVs) with a 5 mm margin were defined on the gated CTs. Organs-at-risk (OARs) are defined as the normal lungs, spinal cord, esophagus, and heart. The prescribed dose was 66 Gy relative-biological-effectiveness (RBE) in 10 fractions at the isocenter and 50% volume of the ICTVs for the PS and PBS, respectively. We compared the target and OAR dose statistics from the dose volume histograms. The PBS+ group had a significantly better mean PTV conformity index than the PBS- and PS groups. The mean dose sparing for PBS+ was better than those for PBS- and PS. Only the normal lung doses of PBS- were worse than those of PS. The overall performance of the OAR sparing was in the order of PBS+, PBS-, and PS. The PBS+ plan showed significantly better target homogeneity and OAR sparing than the PBS- and PS plans. PBS requires collimating systems to treat lung cancers with the most OAR sparing while maintaining the target coverage.

Keywords: Lung cancer; Multileaf collimator; Passive scattering; Pencil beam scanning; Proton therapy.

MeSH terms

  • Humans
  • Lung Neoplasms* / radiotherapy
  • Organs at Risk
  • Proton Therapy*
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy, Intensity-Modulated*