Urinary hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and catecholamines (CAs) are important biomarkers of PAHs exposure. In this study, a novel magnetic boronic acid hypercrosslinked composite (Fe3O4@HCP-BA) is synthesized using a facile one-pot strategy and applied as a sorbent for the simultaneous extraction of OH-PAHs and CAs in urine samples. The synthesized Fe3O4@HCP-BA composites are characterized by rich pore structure, highly specific surface area, good magnetic response, and excellent selectivity and adsorption efficiency (range: 65.26-496.71 and 1227.3-1581.8 µmol g-1 for CAs and OH-PAHs, respectively). The mechanisms governing the adsorption of the OH-PAHs and CAs to the Fe3O4@HCP-BA composites were systematically studied via adsorption kinetics, isotherm models, XPS characterization, and molecular simulation. The resultant Fe3O4@HCP-BA composite-based MSPE/HPLC-FLD method exhibited good linearity (R2 > 0.9916), low limits of detection (0.2-0.3 pg mL-1 and 0.2-0.3 ng mL-1 for OH-PAHs and CAs, respectively), and good precision (intra-day and inter-day RSDs < 11.1%). The analysis of CAs and OH-PAHs in the urine samples from 14 smokers and 14 non-smokers revealed a positive correlation between the concentrations of CAs and OH-PAHs. Our findings not only establish the proposed method as a green, environmentally friendly, and simple strategy for preparing magnetic adsorbents, but also confirm it as a promising alternative method for accurate determination of OH-PAHs and CAs in biological samples.
Keywords: Adsorption mechanisms; Catecholamines; HPLC-FLD; Hydroxylated polycyclic aromatic hydrocarbons; Magnetic boronic hypercrosslinked polymers.