Real-time loop-mediated isothermal amplification for the detection of Giardia duodenalis in fecal specimens

Indian J Med Microbiol. 2024 Jan-Feb:47:100492. doi: 10.1016/j.ijmmb.2023.100492. Epub 2023 Nov 1.

Abstract

Introduction: Giardiasis is a leading cause of subacute or chronic diarrhoea and is frequently associated with impaired physical, cognitive and psychosocial development, especially in children. The diagnosis relies mainly on the microscopic evaluation of stool specimens that have a low sensitivity. In contrast, molecular advancements like the polymerase chain reaction and Real-time loop-mediated isothermal amplification (Real-time LAMP) are promising techniques and reportedly have better diagnostic characteristics.

Methods: We have evaluated the performance of Real-time LAMP for detecting Giardia in ninety stool specimens compared to microscopy and nested PCR.

Results: A total of 35 fecal samples were detected positive by microscopy, 41 by nested PCR and 43 by real-time LAMP. Microscopy and nested PCR detected 33, microscopy and real-time LAMP detected 35, and nested PCR and real-time LAMP detected 41 positive samples.

Conclusion: The real-time LAMP assay was found suitable for the rapid and accurate detection of G. duodenalis with a better sensitivity in comparison to nested PCR and microscopy. Furthermore, besides being sensitive and rapid, LAMP had the advantage of an adequate rapid turn-around time of eleven to 15 ​min as compared to 5 ​h of nested PCR.

Keywords: Giardia; Nested PCR; Real-time loop-mediated isothermal amplification.