Ultrasensitive Acoustic Detection Using an Enlarged Fabry-Perot Cavity with a Graphene Diaphragm

ACS Appl Mater Interfaces. 2023 Oct 26. doi: 10.1021/acsami.3c11220. Online ahead of print.

Abstract

For exerting high sensitivity of ultrathin graphene to detection deformation, an enlarged backing air cavity (EBC) structure is developed to further enhance the mechanical sensitivity (SM) of a graphene-based Fabry-Perot (F-P) acoustic sensor. COMSOL acoustic field simulation on the air cavity size-dependent SM confirms the optimal length and radius of the EBC of 0.2 and 1.5 mm, respectively, with the maximum simulation SM of 26.16 nm/Pa@1 kHz. Acoustic experiments further demonstrate that the frequency response of the fabricated graphene-based F-P acoustic sensor after the use of the EBC is enhanced by 5.73-79.33 times in the range of 0.5-18 kHz, compared with the conventional one without the EBC. Especially the maximum SM is up to 187.32 nm/Pa@16 kHz, which is at least 17% higher than the SM values ranging from 1.1 to 160 nm/Pa in previously reported F-P acoustic sensors using various diaphragm materials. More acoustic characteristics are examined to highlight various merits of the EBC structure, including a signal-to-noise ratio (SNR) of 60-75 dB@0.5-18 kHz, a time stability of less than ±1.3% for 90 min, a detection resolution of 0.01 Hz, and a high-fidelity speech detection with a cross-correlation coefficient of greater than 0.9, thereby revealing its high-performance weak acoustic sensing and speech recognition applications.

Keywords: F−P acoustic sensor; enlarged backing air cavity; graphene; speech detection; ultrahigh sensitivity.