Ultrahigh-acetone-sensitivity sensor based on Pt-loaded TiO2porous nanoparticles synthesized via a facile hydrothermal method

Nanotechnology. 2023 Nov 9;35(4). doi: 10.1088/1361-6528/ad0603.

Abstract

A simple hydrothermal method based on an orthogonal experimental design was used to synthesis Pt-loaded TiO2mesoporous nanoparticles in one step. The successful synthesis of Pt-loaded TiO2nanoparticles was demonstrated by various characterization methods. The effects of the modification of Pt and its explanation are described in detail by means of the test results. Through systematic gas-sensing tests, we found that the Pt-loaded TiO2nanoparticles outperform pure TiO2nanoparticles, with a high response value (S= 42.5) to 200 ppm acetone at 260 °C and with a film thickness of 0.45 mm, far superior to that of pure TiO2. The response time (8 s) and recovery time (11 s) of the material are also relatively good with excellent selectivity and long-term stability (30 days). The frequent use of acetone as an organic solution in factories and laboratories, as well as the possibility of making a preliminary diagnosis of diabetes by detecting acetone levels in exhaled gas, make this work promising for environmental monitoring and medical diagnosis.

Keywords: Pt-loaded TiO2; acetone sensor; hydrothermal method; mesoporous nanoparticles; orthogonal experimental design.