Effect of Diameter and Type of Suture on Knot and Loop Security

J Clin Med. 2023 Oct 9;12(19):6418. doi: 10.3390/jcm12196418.

Abstract

The loop and knot securities of two polyfilament and two monofilament sutures of four diameters (3.0, 2.0, 0, 1) were evaluated with a tensiometer for four four-throw knots, known to be secure with a 2.0 polyfilament suture. Loop security of Monocryl 1 is low, being 14.7 ± 3.0 Newton (N) for a three-throw half-knot (H3) and 15.4 ± 2.4 N and 28.3 ± 10 N for two (SSs) and four (SSsSsSs) symmetrical sliding half-hitches. This is lower than 18, 24, and 46 N for similar knots with Vicryl. Polyfilament sutures have excellent knot security for all four diameters. Occasionally, some slide open with slightly lower knot security, especially for larger diameters, although this is not clinically problematic. Knot security of monofilament sutures was unpredictable for all four knots, especially for larger diameters, resulting in many clinically insecure knots. A secure monofilament knot requires a six-throw knot with two symmetrical sliding half-hitches or two symmetrical half-knots secured with four asymmetric blocking half-hitches. In conclusion, with polyfilament sutures, four- or five-throw half-knot or half-hitch sequences result in secure knots. For monofilament sutures, loop and knot security is much less, half-knot combinations should be avoided, and secure knots require six-throw knots with four asymmetric blocking half-hitches.

Keywords: half-hitches; half-knots; knot rotation; knot security; knot sequences; laparoscopic surgery; loop security.

Grants and funding

This research received no external funding.