Evaluating Earplug Performance over a 2-Hour Work Period with a Fit-Test System

Semin Hear. 2023 Jun 1;44(4):470-484. doi: 10.1055/s-0043-1769586. eCollection 2023 Nov.

Abstract

Workers rely on hearing protection devices to prevent occupational noise-induced hearing loss. This study aimed to evaluate changes in attenuation over time for properly fit devices when worn by workers exposed to hazardous noise. Earplug fit testing was accomplished on 30 workers at a brewery facility with three types of foam and three types of premolded earplugs. The personal attenuation ratings (PARs) were measured before and after a 2-hour work period while exposed to hazardous noise levels. The minimum acceptable initial PAR was 15 dB. Average decreases in PAR ranged from -0.7 to -2.6 dB across all six earplug types. Significant changes in PAR were observed for the Foam-1 ( p = 0.009) and Premold-3 ( p = 0.004) earplugs. A linear mixed regression model using HPD type and study year as fixed effects and subject as random effect was not significant for either fixed effect ( α = 0.05). Ninety-five percent of the final PAR measurements maintained the target attenuation of 15 dB. Properly fitting earplugs can be effective at reducing worker's noise exposures over time. The potential for a decrease in attenuation during the work shift should be considered when training workers and establishing the adequacy of protection from hazardous noise exposures.

Keywords: duration; fit testing; hearing protection; noise exposure; occupational hearing loss; personal attenuation rating.

Publication types

  • Review