Impact of Respiratory Motion on the Skin Dose for Breast Cancer in Tomotherapy: A Study in the In-house Moving Phantom

Technol Cancer Res Treat. 2023 Jan-Dec:22:15330338231197520. doi: 10.1177/15330338231197520.

Abstract

Purpose: The dose expansion methods as the skin flash and virtual bolus were used to solve intrafraction movement for breast planning due to breathing motion. We investigated the skin dose in each planning method by using optically stimulated luminescence on an in-house moving phantom for breast cancer treatment in tomotherapy. The impact of respiratory motion on skin dose between static and dynamic phantom's conditions was evaluated. Methods: A phantom was developed with movement controlled by the respirator for generating the respiratory waveforms to simulate respiratory motion. Five optically stimulated luminescence dosimeters were placed on the phantom surface to investigate the skin dose for the TomoDirect and TomoHelical under static and dynamic conditions. Eight treatment plans were generated with and without skin flash or virtual bolus by varying the thickness. The difference in skin dose between the two phantom conditions for each plan was explored. Results: All plans demonstrated a skin dose of more than 87% of the prescription dose under static conditions. However, the skin dose was reduced to 84.1% (TomoDirect) and 78.9% (TomoHelical) for dynamic conditions. The treatment plans without skin flash or virtual bolus showed significant skin dose differences under static and dynamic conditions by 4.83% (TomoDirect) and 9.43% (TomoHelical), whereas the skin flash with two leaves (TomoDirect 2L) or virtual bolus of at least 1.0 cm thickness (VB1.0) application compensated the skin dose in case of intrafraction movements by presenting a skin dose difference of less than 2% between the static and dynamic conditions. Conclusion: The skin dose was reduced under dynamic conditions due to breathing motion. The skin flash method with TomoDirect 2L or virtual bolus application with 1.0 cm thickness was useful for maintaining skin dose following the prescription by compensating for intrafraction movement due to respiratory motion for breast cancer in tomotherapy.

Keywords: OSL; breast cancer; movable phantom; skin dose; tomotherapy.

MeSH terms

  • Breast Neoplasms* / radiotherapy
  • Female
  • Humans
  • Motion
  • Phantoms, Imaging
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted / methods
  • Radiotherapy, Intensity-Modulated* / methods