Low-Cost Particulate Matter Sensors for Monitoring Residential Wood Burning

Environ Sci Technol. 2023 Oct 10;57(40):15162-15172. doi: 10.1021/acs.est.3c03661. Epub 2023 Sep 27.

Abstract

Conventional monitoring systems for air quality, such as reference stations, provide reliable pollution data in urban settings but only at relatively low spatial density. This study explores the potential of low-cost sensor systems (LCSs) deployed at homes of residents to enhance the monitoring of urban air pollution caused by residential wood burning. We established a network of 28 Airly (Airly-GSM-1, SP. Z o.o., Poland) LCSs in Kristiansand, Norway, over two winters (2021-2022). To assess performance, a gravimetric Kleinfiltergerät measured the fine particle mass concentration (PM2.5) in the garden of one participant's house for 4 weeks. Results showed a sensor-to-reference correlation equal to 0.86 for raw PM2.5 measurements at daily resolution (bias/RMSE: 9.45/11.65 μg m-3). High-resolution air quality maps at a 100 m resolution were produced by combining the output of an air quality model (uEMEP) using data assimilation techniques with the network data that were corrected and calibrated by using a proposed five-step network data processing scheme. Leave-one-out cross-validation demonstrated that data assimilation reduced the model's RMSE, MAE, and bias by 44-56, 38-48, and 41-52%, respectively.

Keywords: Airly sensor; PM2.5 spatiotemporal variation; air pollution; calibration; data assimilation; gravimetric method; uEMEP air quality model.