Patient-specific finite element analysis of human corneal lenticules: An experimental and numerical study

J Mech Behav Biomed Mater. 2023 Nov:147:106141. doi: 10.1016/j.jmbbm.2023.106141. Epub 2023 Sep 21.

Abstract

The number of elective refractive surgeries is constantly increasing due to the drastic increase in myopia prevalence. Since corneal biomechanics are critical to human vision, accurate modeling is essential to improve surgical planning and optimize the results of laser vision correction. In this study, we present a numerical model of the anterior cornea of young patients who are candidates for laser vision correction. Model parameters were determined from uniaxial tests performed on lenticules of patients undergoing refractive surgery by means of lenticule extraction, using patient-specific models of the lenticules. The models also took into account the known orientation of collagen fibers in the tissue, which have an isotropic distribution in the corneal plane, while they are aligned along the corneal curvature and have a low dispersion outside the corneal plane. The model was able to reproduce the experimental data well with only three parameters. These parameters, determined using a realistic fiber distribution, yielded lower values than those reported in the literature. Accurate characterization and modeling of the cornea of young patients is essential to study better refractive surgery for the population undergoing these treatments, to develop in silico models that take corneal biomechanics into account when planning refractive surgery, and to provide a basis for improving visual outcomes in the rapidly growing population undergoing these treatments.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cornea* / surgery
  • Corneal Stroma* / surgery
  • Finite Element Analysis
  • Humans