Prediction of labour outcomes using prelabour computerised cardiotocogram and maternal and fetal Doppler indices: A prospective cohort study

BJOG. 2024 Mar;131(4):472-482. doi: 10.1111/1471-0528.17669. Epub 2023 Sep 17.

Abstract

Objectives: To investigate the association and the potential value of prelabour fetal heart rate short-term variability (STV) determined by computerised cardiotocography (cCTG) and maternal and fetal Doppler in predicting labour outcomes.

Design: Prospective cohort study.

Setting: The Prince of Wales Hospital, a tertiary maternity unit, in Hong Kong SAR.

Population: Women with a term singleton pregnancy in latent phase of labour or before labour induction were recruited during May 2019-November 2021.

Methods: Prelabour ultrasonographic assessment of fetal growth, Doppler velocimetry and prelabour cCTG monitoring including Dawes-Redman CTG analysis were registered shortly before induction of labour or during the latent phase of spontaneous labour.

Main outcome measures: Umbilical cord arterial pH, emergency delivery due to pathological CTG during labour and neonatal intensive care unit (NICU)/special care baby unit (SCBU) admission.

Results: Of the 470 pregnant women invited to participate in the study, 440 women provided informed consent and a total of 400 participants were included for further analysis. Thirty-four (8.5%) participants underwent emergency delivery for pathological CTG during labour. A total of 6 (1.50%) and 148 (37.00%) newborns required NICU and SCBU admission, respectively. Middle cerebral artery pulsatility index (MCA-PI) and MCA-PI z-score were significantly lower in pregnancies that required emergency delivery for pathological CTG during labour compared with those that did not (1.23 [1.07-1.40] versus 1.40 [1.22-1.64], p = 0.002; and 0.55 ± 1.07 vs. 0.12 ± 1.06), p = 0.049]. This study demonstrated a weakly positive correlation between umbilical cord arterial pH and prelabour log10 STV (r = 0.107, p = 0.035) and the regression analyses revealed that the contributing factors for umbilical cord arterial pH were smoking (p = 0.006) and prelabour log10 STV (p = 0.025).

Conclusions: In pregnant women admitted in latent phase of labour or for induction of labour at term, prelabour cCTG STV had a weakly positive association with umbilical cord arterial pH but was not predictive of emergency delivery due to pathological CTG during labour.

Keywords: Doppler ultrasound; caesarean section; computerised cardiotocography; cord pH; emergency delivery; neonatal intensive care unit; prelabour.