Comparison of the carotid corrected flow time and tidal volume challenge for assessing fluid responsiveness in robot-assisted laparoscopic surgery

J Robot Surg. 2023 Dec;17(6):2763-2772. doi: 10.1007/s11701-023-01710-y. Epub 2023 Sep 14.

Abstract

We aimed to compare the ability of carotid corrected flow time assessed by ultrasound and the changes in dynamic preload indices induced by tidal volume challenge predicting fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery in the modified head-down lithotomy position. This prospective single-center study included patients undergoing robot-assisted laparoscopic surgery in the modified head-down lithotomy position. Carotid Doppler parameters and hemodynamic data, including corrected flow time, pulse pressure variation, stroke volume variation, and stroke volume index at a tidal volume of 6 mL/kg predicted body weight and after increasing the tidal volume to 8 mL/kg predicted body weight (tidal volume challenge), respectively, were measured. Fluid responsiveness was defined as a stroke volume index ≥ 10% increase after volume expansion. Among the 52 patients included, 26 were classified as fluid responders and 26 as non-responders based on the stroke volume index. The area under the receiver operating characteristic curve measured to predict the fluid responsiveness to corrected flow time and changes in pulse pressure variation (ΔPPV6-8) after tidal volume challenge were 0.82 [95% confidence interval (CI) 0.71-0.94; P < 0.0001] and 0.85 (95% CI 0.74-0.96; P < 0.0001), respectively. The value for pulse pressure variation at a tidal volume of 8 mL/kg was 0.79 (95% CI 0.67-0.91; P = 0.0003). The optimal cut-off values for corrected flow time and ΔPPV6-8 were 357 ms and > 1%, respectively. Both the corrected flow time and Changes in pulse pressure variation after tidal volume challenge reliably predicted fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery in the modified head-down lithotomy position. And pulse pressure variation at a tidal volume of 8 mL/kg maybe also a useful predictor.Trial registration: Chinese Clinical Trial Register (CHiCTR2200060573, Principal investigator: Hongliang Liu, Date of registration: 05/06/2022).

Keywords: Carotid corrected flow time; Doppler ultrasound; Fluid responsiveness; Laparoscopic surgery; Robotics; Tidal volume challenge.

Publication types

  • Clinical Trial

MeSH terms

  • Body Weight
  • Humans
  • Laparoscopy*
  • Prospective Studies
  • Robotic Surgical Procedures* / methods
  • Robotics*
  • Tidal Volume