Assessment of the iridocorneal angle pigmentation and structures after the implantation of EVO+ Visian Implantable Collamer Lens

Int Ophthalmol. 2023 Dec;43(12):4711-4718. doi: 10.1007/s10792-023-02871-3. Epub 2023 Sep 11.

Abstract

Purpose: To evaluate the effect of EVO+ Visian Implantable Collamer Lens (ICL) implantation on the iridocorneal angle pigmentation and structures.

Methods: Myopic refractive surgery candidates who underwent posterior chamber EVO+ ICL implantation were evaluated preoperatively and 3 and 6 months postoperatively. High-resolution images of the iridocorneal angle (nasal, superior, temporal and inferior quadrants) were acquired during gonioscopy. A masked observer, blinded to study visits and patients' information, evaluated the angle width, apparent iris root insertion, iris configuration, and trabecular meshwork pigmentation according to the Spaeth scale in two different occasions. The intra-rater reliability was estimated using the weighted Gwet's Agreement Coefficient (AC2). Differences between visits were analyzed using the Cochran Q test or the Friedman test.

Results: Twenty-one patients (13 females and 8 males) aging 31.3 ± 6.3 years old were recruited. The intra-rater reliability of gonioscopy assessment was excellent for every parameter assessed (AC2 ≥ 0.97). No significant differences were found among the study visits for any quadrant in the angle width (p ≥ 0.74), apparent iris root insertion (p ≥ 0.22), iris configuration (p ≥ 0.21) and trabecular meshwork pigmentation (p ≥ 0.24). Mean pigmentation of trabecular meshwork for the four quadrants did not vary either among visits (p = 0.25).

Conclusions: The EVO+ ICL implantation after uneventful procedures appears not to clinically affect the iridocorneal angle pigmentation and/or structures during a short-medium follow-up using gonioscopy assessment. The intra-rater reliability of glaucoma specialists assessing iridocorneal angle structures using gonioscopy images is very high.

Keywords: Angle structures; EVO+ Visian Implantable Collamer Lens (ICL); Gonioscopy; Intra-rater reliability; Pigmentation.

MeSH terms

  • Adult
  • Anterior Chamber
  • Female
  • Gonioscopy
  • Humans
  • Iris / surgery
  • Lens Implantation, Intraocular* / methods
  • Male
  • Pigmentation
  • Pigmentation Disorders*
  • Reproducibility of Results
  • Trabecular Meshwork / surgery