Evaluating the Efficacy of Tension Band Wiring Fixation for Chaput Tubercle Fractures

J Clin Med. 2023 Aug 24;12(17):5490. doi: 10.3390/jcm12175490.

Abstract

Background: Chaput tubercle fractures, located at the attachment site of the anterior inferior tibiofibular ligament (AITFL) on the distal tibia, have the potential to destabilize the syndesmosis joint. This study aims to assess the effectiveness of tension band wiring (TBW) as a surgical intervention for managing Chaput fractures and the consequent syndesmosis instability.

Methods: A retrospective review of patient charts was undertaken for those who had undergone ankle fracture surgery from April 2019 through May 2022. The surgical procedure involved direct fixation of the Chaput fractures using the TBW method. Radiological assessments were performed using postoperative simple radiographs and computed tomography (CT) scans, while clinical outcomes were evaluated using the Olerud-Molander Ankle Score (OMAS) and the visual analog scale (VAS).

Results: The study included 21 patients. The average OMAS improved significantly, rising from 5.95 preoperatively to 83.57 postoperatively. Similarly, the average VAS score dropped from 7.95 before the surgery to 0.19 thereafter. Minor wound complications were reported by three patients, and one case of superficial infection was resolved with antibiotic therapy.

Conclusions: Our findings suggest that the TBW technique is an effective surgical approach for treating Chaput fractures and associated syndesmosis instability. It provides reliable fixation strength and leads to improved long-term functional outcomes. Further research is needed to compare the TBW technique with alternative methods and optimize the treatment strategies for these complex ankle fractures.

Keywords: ankle fracture; avulsion fracture; chaput tubercle; syndesmosis injury; tension band wiring.