Long-Term Aesthetic Cicatrization Analysis of Lower Eyelid Incision for Orbital Floor Fracture Approach

J Craniofac Surg. 2023 Nov-Dec;34(8):e753-e757. doi: 10.1097/SCS.0000000000009629. Epub 2023 Aug 25.

Abstract

Orbital fractures are among the most frequent facial injuries. Of the 3 most widely described approaches in the literature, the lower eyelid approach is the authors' preference. This study retrospectively analyzed the patients treated at the Trauma Center of the Umberto I Hospital, Sapienza University of Rome from January 2010 to December 2020. Inclusion criteria were as follows: diagnosis of pure/impure orbital bone fracture, complete clinical and radiological documentation, and a minimum of 12 months follow-up. Sex, age, etiology, treatment, and associated complications were analyzed using IBM SPSS Statistics. Two internationally validated scales were used for the functional and esthetic long-term evaluation: the Patient and Observer Scar Assessment Scale (POSAS) and the Vancouver one. The scales were compiled by the patient himself and by 3 independent expert observers. Of the 543 patients who underwent surgery in the specified period, 208 fully met the inclusion criteria. One hundred forty-two (68.2%) were males and 66 (31.8%) were females, with a mean age of 40.68 years. The main cause was represented by assaults (33.1%). One hundred seventy-nine patients had a pure orbital fracture (83.8%) and 29 an impure one (16.2%). The most frequent symptoms at the time of diagnosis were diplopia (31.2%), followed by anesthesia of the second trigeminal branch (24.3%). Open reduction with internal fixation was the preferred treatment and proved to be effective in reducing the main signs and symptoms of the fracture in a statistically significant way ( P < 0.05). Long-term esthetic results of the lower eyelid, using the Vancouver and POSASs, were respectively as follows: Vancouver Scar Scale mean total score was 2.41 (range: 0-8), observer POSAS mean total score was 1.83 (range: 1.2-3.9), observer general opinion mean score was 1.66, patient POSAS mean total score was 2.23 (range: 1.33-3.7), and patient general opinion mean score was 2.87. The lower eyelid approach has proven to be reproducible, with a fast-learning curve and a low complication rate. The analysis conducted highlighted an excellent long-term esthetic-functional result. Further studies will be needed to statistically compare the results obtained with other orbital floor surgical approaches.

MeSH terms

  • Adult
  • Cicatrix
  • Esthetics, Dental
  • Eyelids / surgery
  • Female
  • Fractures, Multiple*
  • Humans
  • Male
  • Orbital Fractures* / diagnostic imaging
  • Orbital Fractures* / surgery
  • Retrospective Studies