Short-Term Thermal Effect of Continuous Ultrasound from 3 MHz to 1 and 0.5 W/cm2 Applied to Gastrocnemius Muscle

Diagnostics (Basel). 2023 Aug 10;13(16):2644. doi: 10.3390/diagnostics13162644.

Abstract

Continuous ultrasound is recognized for its thermal effect and use in the tissue repair process. However, there is controversy about its dosage and efficacy. This study used infrared thermography, a non-invasive technique, to measure the short-term thermal effect of 3 MHz continuous ultrasound vs. a placebo, referencing the intensity applied. It was a single-blind, randomized clinical trial of 60 healthy volunteers (19-24 years old) divided into three equal groups. Group 1:1 W/cm2 for 5 min; Group 2: 0.5 W/cm2 for 10 min; and Group 3: the placebo for 5 min. The temperature was recorded through five thermographic images per patient: pre- and post-application, 5, 10, and 15 min later. After statistical analysis, a more significant decrease in temperature (p<0.05 ) was observed in the placebo group compared with the remaining groups after the application of continuous ultrasound. Group 1 was the one that generated the highest significant thermal effect (p<0.001), with an increase of 3.05 °C at 15 min, compared with the other two groups. It is concluded that to generate a thermal effect in the muscle, intensities of ≥1 W/cm2 are required, since the dosage maintained a temperature increase for more than 5 min.

Keywords: continuous ultrasound; infrared thermography; medical imaging; muscle; thermal imaging.