Handgrip exercise does not alter CO2 -mediated cerebrovascular flow-mediated dilation

Exp Physiol. 2023 Oct;108(10):1337-1346. doi: 10.1113/EP091125. Epub 2023 Aug 25.

Abstract

Handgrip exercise (HG), a small muscle exercise, improves cognitive function and is expected to provide a useful exercise mode to maintain cerebral health. However, the effect of HG on cerebral blood flow regulation is not fully understood. The present study aimed to examine the effect of acute HG on cerebral endothelial function as one of the essential cerebral blood flow regulatory functions. Thirteen healthy young participants performed interval HG, consisting of 4 sets of 2 min HG at 25% of maximum voluntary contraction with 3 min recovery between each set. Cognitive performance was evaluated before and at 5 and 60 min after interval HG using the Go/No-Go task (reaction time and accuracy). The diameter and blood velocity of the internal carotid artery (ICA) were measured using a duplex Doppler ultrasound system. To assess cerebral endothelial function, hypercapnia (30 s of hypercapnia stimulation, end-tidal partial pressure of CO2 : +9 mmHg)-induced cerebrovascular flow-mediated dilatation (cFMD) was induced, calculated as relative peak dilatation from baseline diameter. The shear rate (SR) was calculated using the diameter and blood velocity of the ICA. As a result, cognitive performance improved only at 5 min after interval HG (reaction time, P = 0.008; accuracy, P = 0.186), whereas ICA SR during interval HG and cFMD after interval HG were unchanged (P = 0.313 and P = 0.440, respectively). These results suggest that enhancement in cerebral endothelial function is not an essential mechanism responsible for acute HG-induced cognitive improvement. NEW FINDINGS: What is the central question of this study? Does handgrip exercise, a small muscle exercise, improve cerebral endothelial function? What is the main finding and its importance? Acute interval isometric handgrip exercise (2 min of exercise at 25% maximum voluntary contraction, followed by 3 min of recovery, repeated for a total of 4 sets) did not improve cerebral endothelial function. Since the cerebrovascular shear rate did not change during exercise, it is possible that acute handgrip exercise is not sufficient stimulation to improve cerebral endothelial function.

Keywords: cerebral endothelial function; cerebrovascular shear rate; executive function; internal carotid artery; isometric exercise.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Blood Flow Velocity / physiology
  • Carbon Dioxide*
  • Carotid Artery, Internal* / physiology
  • Cerebrovascular Circulation / physiology
  • Dilatation / methods
  • Hand Strength / physiology
  • Humans
  • Hypercapnia

Substances

  • Carbon Dioxide