Clinical Predictors and Outcomes After Left Ventricular Assist Device Implantation and Tracheostomy

Tex Heart Inst J. 2023 Aug 22;50(4):e238100. doi: 10.14503/THIJ-23-8100.

Abstract

Background: Postoperative respiratory failure is a major complication that affects up to 10% of patients who undergo cardiac surgery and has a high in-hospital mortality rate. Few studies have investigated whether patients who require tracheostomy for postoperative respiratory failure after continuous-flow left ventricular assist device (CF-LVAD) implantation have worse survival outcomes than patients who do not.

Objective: To identify risk factors for respiratory failure necessitating tracheostomy in CF-LVAD recipients and to compare survival outcomes between those who did and did not require tracheostomy.

Methods: Consecutive patients who underwent primary CF-LVAD placement at a single institution between August 1, 2002, and December 31, 2019, were retrospectively reviewed. Propensity score matching accounted for baseline differences between the tracheostomy and nontracheostomy groups. Multivariate logistic regression was used to identify tracheostomy risk factors and 90-day survival; Kaplan-Meier analysis was used to assess midterm survival.

Results: During the study period, 664 patients received a CF-LVAD; 106 (16.0%) underwent tracheostomy for respiratory failure. Propensity score matching produced 103 matched tracheostomy-nontracheostomy pairs. Patients who underwent tracheostomy were older (mean [SD] age, 57.9 [12.3] vs 54.6 [13.9] years; P = .02) and more likely to need preoperative mechanical circulatory support (61.3% vs 47.8%; P = .01) and preoperative intubation (27.4% vs 8.8%; P < .001); serum creatinine was higher in the tracheostomy group (mean [SD], 1.7 [1.0] vs 1.4 [0.6] mg/dL; P < .001), correlating with tracheostomy need (odds ratio, 1.76; 95% CI, 1.21-2.56; P = .003). Both before and after propensity matching, 30-day, 60-day, 90-day, and 1-year survival were worse in patients who underwent tracheostomy. Median follow-up was 0.8 years (range, 0.0-11.2 years). Three-year Kaplan-Meier survival was significantly worse for the tracheostomy group before (22.0% vs 61.0%; P < .001) and after (22.4% vs 48.3%; P < .001) matching.

Conclusion: Given the substantially increased probability of death in patients who develop respiratory failure and need tracheostomy, those at high risk for respiratory failure should be carefully considered for CF-LVAD implantation. Comprehensive management to decrease respiratory failure before and after surgery is critical.

Keywords: assisted circulation; heart failure; perioperative care; ventricular assist device.

MeSH terms

  • Heart-Assist Devices*
  • Hospital Mortality
  • Humans
  • Middle Aged
  • Retrospective Studies
  • Thoracic Surgical Procedures*
  • Tracheostomy / adverse effects

Grants and funding

Funding/Support: The authors received no specific funding for this work.