Three-Dimensional Analysis of Upper and Lower Arches Using Digital Technology: Measurement of the Index of Bolton and Correspondence between Arch Shapesand Orthodontic Arches

Dent J (Basel). 2023 Aug 8;11(8):188. doi: 10.3390/dj11080188.

Abstract

Thanks to the great development of digital technology, viaCAD (computer-aided design) and CAM (computer-aided manufacturing) systems, digital models canbe used as an aid for orthodontic planning decision-making processes as there are numerous studies in the literature that support the validity ofthe digital model measurements of anterior teeth and the total coefficient of Bolton analysis. The aim of the present study isto compare the average length value of the current upper and lower arches with that of a hypothetical nickel-titanium wire and to confirm the reliability and accuracy of digitally taken measurements of the anterior and total Bolton coefficients.In this retrospective study, dental casts of 138 Caucasian adolescent patients were scanned with an extraoral scanner, and Ortho3Shape software was adopted for the following dental cast measurements: actual and ideal lengths of the lower arches and anterior and total Bolton coefficients.In the present study, we found that the mean value of the anterior coefficients of the Bolton index was compatible with those of previous studies, confirming the reliability of digital measurements.Therefore, digital CAD/CAM models may be a viable alternative to plaster models, as they can facilitate model preservation and recovery. For future studies, it would be better to use intraoral scanners (IOSs) to ensure greater accuracy, since they only require one step and allow obtaining better results for the patients.

Keywords: Bolton index; digital models; extraoral scanner; orthodontics CAD software.

Grants and funding

This research received no external funding.