True diagnostic ability of EUS-guided fine-needle aspiration/biopsy sampling for small pancreatic lesions ≤10 mm and salvage diagnosis by pancreatic juice cytology: a multicenter study

Gastrointest Endosc. 2024 Jan;99(1):73-80. doi: 10.1016/j.gie.2023.08.006. Epub 2023 Aug 18.

Abstract

Background and aims: The diagnostic performance of EUS-guided fine-needle aspiration/biopsy sampling (EUS-FNAB) for pancreatic ductal adenocarcinoma (PDAC) ≤10 mm in diameter is relatively low. Pancreatic juice cytology (PJC) has gained attention because of its high sensitivity for small PDACs. We aimed to clarify the diagnostic ability of EUS-FNAB and the salvage ability of PJC for PDAC ≤10 mm.

Methods: Data obtained from attempted EUS-FNAB for patients with EUS-confirmed pancreatic tumors ≤10 mm (excluding pancreatic metastases/malignant lymphomas) were retrospectively analyzed. Patients who experienced technical failure or had a negative EUS-FNAB result and had a strong likelihood of PDAC based on imaging characteristics underwent PJC. PDAC was diagnosed using resected histologic specimens, EUS-FNAB-positive tumor growth on the imaging examination, or additional EUS-FNAB-positive results after increase in tumor size. The primary endpoint was the diagnostic ability of EUS-FNAB for PDAC ≤10 mm. The salvage ability of PJC was also assessed.

Results: Overall, 86 of 271 patients with pancreatic tumors ≤10 mm who underwent attempted EUS-FNAB were diagnosed with PDAC. The technical success rate, sensitivity, specificity, and accuracy of EUS-FNAB for PDAC ≤10 mm were 80.8%, 82.3%, 94.9%, and 91.3%, respectively. Among the 35 PDAC patients who experienced technical failure or false-negative results of EUS-FNAB, 26 (74.3%) were correctly diagnosed using salvage PJC.

Conclusions: The true success rate and sensitivity of EUS-FNAB for PDAC ≤10 mm were relatively low. When EUS-FNAB for a pancreatic lesion ≤10 mm strongly suspected to be PDAC is unsuccessful or yields a negative result, PJC is recommended. (Clinical trial registration number: UMIN000049965.).

Publication types

  • Multicenter Study

MeSH terms

  • Biopsy, Fine-Needle
  • Carcinoma, Pancreatic Ductal* / diagnosis
  • Carcinoma, Pancreatic Ductal* / pathology
  • Endoscopic Ultrasound-Guided Fine Needle Aspiration / methods
  • Humans
  • Pancreas / pathology
  • Pancreatic Juice
  • Pancreatic Neoplasms* / diagnosis
  • Pancreatic Neoplasms* / pathology
  • Retrospective Studies