Feasibility of a kinect-based system in assessing physical function of the elderly for home-based care

BMC Geriatr. 2023 Aug 16;23(1):495. doi: 10.1186/s12877-023-04179-4.

Abstract

Background: With concerns about accurate diagnosis through telehealth, the Kinect sensor offers a reliable solution for movement analysis. However, there is a lack of practical research investigating the suitability of a Kinect-based system as a functional fitness assessment tool in homecare settings. Hence, the objective of this study was to evaluate the feasibility of using a Kinect-based system to assess physical function changes in the elderly.

Methods: The study consisted of two phases. Phase one involved 35 young healthy adults, evaluating the reliability and validity of a Kinect-based fitness evaluation compared to traditional physical examination using the intraclass correlation coefficient (ICC). Phase two involved 665 elderly subjects, examining the correlation between the Kinect-based fitness evaluation and physical examination through Pearson's correlation coefficients. A Kinect sensor (Microsoft Xbox One Kinect V2) with customized software was employed to capture and compute the movement of joint centers. Both groups performed seven functional assessments simultaneously monitored by a physical therapist and the Kinect system. System usability and user satisfaction were assessed using the System Usability Scale (SUS) and Questionnaire for User Interface Satisfaction (QUIS), respectively.

Results: Kinect-based system showed overall moderate to excellent within-day reliability (ICC = 0.633-1.0) and between-day reliability (ICC = 0.686-1.0). The overall agreement between the two devices was highly correlated (r ≧ 0.7) for all functional assessment tests in young healthy adults. The Kinect-based system also showed a high correlation with physical examination for the functional assessments (r = 0.858-0.988) except functional reach (r = 0.484) and walking speed(r = 0.493). The users' satisfaction with the system was excellent (SUS score = 84.4 ± 18.5; QUIS score = 6.5-6.7).

Conclusions: The reliability and validity of Kinect for assessing functional performance are generally favorable. Nonetheless, caution is advised when employing Kinect for tasks involving depth changes, such as functional reach and walking speed tests for their moderate validity. However, Kinect's fundamental motion detection capabilities demonstrate its potential for future applications in telerehabilitation in different healthcare settings.

Keywords: Kinect; Motion analysis; Physical fitness; Reproducibility of results; Telemedicine; Validation studies.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Exercise*
  • Feasibility Studies
  • Health Facilities*
  • Health Status
  • Humans
  • Reproducibility of Results