A validated method for detection of cannflavins in hemp extracts

J Pharm Biomed Anal. 2023 Oct 25:235:115631. doi: 10.1016/j.jpba.2023.115631. Epub 2023 Aug 12.

Abstract

A selective and sensitive liquid chromatography mass spectrometry assay was developed for the detection of cannflavin A, B, and C in hemp extract specimens. A deuterated analog cannabidiol-D3 was used as the internal standard and the isocratic method used a mobile phase consisting of acetonitrile and water with 0.1 % formic acid [83:17]. Detection was carried out by electrospray positive ionization in single-ion monitoring mode through a C-18 analytical column. The assay (total run time <20 min) had excellent linearity and a lower limit of quantification of 0.5 μg/mL and a limit of detection of 0.25 μg/mL with a 10 μL injection. The method possessed suitable measures of stability, sensitivity, and selectivity for detecting cannflavins in several specimen types. The method was successfully applied to the analysis of samples of cannflavin release from prototype topical formulations.

Keywords: Cannabis; Cannflavin; Liquid chromatography; Mass spectrometry.

MeSH terms

  • Cannabis* / chemistry
  • Chromatography, High Pressure Liquid / methods
  • Chromatography, Liquid / methods
  • Plant Extracts
  • Reproducibility of Results
  • Spectrometry, Mass, Electrospray Ionization / methods

Substances

  • cannflavin
  • Plant Extracts