Distal stent graft-induced new entry (dSINE) after frozen elephant trunk: a scoping review

Cardiovasc Diagn Ther. 2023 Apr 28;13(2):408-417. doi: 10.21037/cdt-22-234. Epub 2023 Mar 30.

Abstract

Background: The introduction of hybrid total arch replacement with the frozen elephant trunk (FET) technique has improved the field of aortic surgery by allowing single-stage treatment of complex aortic pathologies. Although FET has been associated with favorable aortic remodeling, it is also associated with the potential development of distal stent graft-induced new entries (dSINEs). The aim of our review is to collect data about the incidence and the supposed conditions for the occurrence of dSINE after total hybrid arch replacement with FET technique.

Methods: The literature review was performed using PubMed databases from inception to January 2022. A descriptive approach to detect and display supposed risk factors and predictors for dSINE occurrence has been adopted.

Results: Eight studies summarized the state-of-the-art of dSINE in a total number of 544 FET procedures performed to treat acute and chronic aortic dissections. The scoping review showed dSINEs occurrence in 69 patients (12.7%). The mean time between surgery and the diagnosis ranged from 12.6 to 30.6 months. Most patients that developed dSINE received endovascular treatment, whereas a couple of them needed open surgery. According to our experience, from January 2007 to December 2021, in 225 FET procedures a total of 54 cases of dSINE, both with Thoraflex and E-vita grafts have been detected. The mean time between the surgical procedure and the diagnosis was 27.2±33.6 months.

Conclusions: dSINEs are frequent complications after FET. Although not emergent, they require proper treatment. Due to dSINE's asymptomatic nature and potential harm, a rigorous follow-up including angio-computed tomography (CT) should be planned.

Keywords: Aortic; arch; frozen elephant trunk (FET); thoracic endovascular aortic repair (TEVAR).

Publication types

  • Review