Strategies for Mitigating Commercial Sensor Chip Variability with Experimental Design Controls

Sensors (Basel). 2023 Jul 26;23(15):6703. doi: 10.3390/s23156703.

Abstract

Surface plasmon resonance (SPR) is a popular real-time technique for the measurement of binding affinity and kinetics, and bench-top instruments combine affordability and ease of use with other benefits of the technique. Biomolecular ligands labeled with the 6xHis tag can be immobilized onto sensing surfaces presenting the Ni2+-nitrilotriacetic acid (NTA) functional group. While Ni-NTA immobilization offers many advantages, including the ability to regenerate and reuse the sensors, its use can lead to signal variability between experimental replicates. We report here a study of factors contributing to this variability using the Nicoya OpenSPR as a model system and suggest ways to control for those factors, increasing the reproducibility and rigor of the data. Our model ligand/analyte pairs were two ovarian cancer biomarker proteins (MUC16 and HE4) and their corresponding monoclonal antibodies. We observed a broad range of non-specific binding across multiple NTA chips. Experiments run on the same chips had more consistent results in ligand immobilization and analyte binding than experiments run on different chips. Further assessment showed that different chips demonstrated different maximum immobilizations for the same concentration of injected protein. We also show a variety of relationships between ligand immobilization level and analyte response, which we attribute to steric crowding at high ligand concentrations. Using this calibration to inform experimental design, researchers can choose protein concentrations for immobilization corresponding to the linear range of analyte response. We are the first to demonstrate calibration and normalization as a strategy to increase reproducibility and data quality of these chips. Our study assesses a variety of factors affecting chip variability, addressing a gap in knowledge about commercially available sensor chips. Controlling for these factors in the process of experimental design will minimize variability in analyte signal when using these important sensing platforms.

Keywords: Ni2+-nitrilotriacetic acid (NTA); Nicoya Life Sciences; biosensor; immobilization; surface plasmon resonance (SPR); variability.

MeSH terms

  • Antibodies, Monoclonal
  • Ligands
  • Nitrilotriacetic Acid / chemistry
  • Reproducibility of Results
  • Research Design*
  • Surface Plasmon Resonance* / methods

Substances

  • Ligands
  • Nitrilotriacetic Acid
  • Antibodies, Monoclonal