Comparison of test performance of two commonly used multiplex assays to measure micronutrient and inflammatory markers in serum: results from a survey among pregnant women in South Africa

Br J Nutr. 2024 Jan 28;131(2):248-255. doi: 10.1017/S0007114523001782. Epub 2023 Aug 10.

Abstract

The combined sandwich-ELISA (s-ELISA; VitMin Lab, Germany) and the Quansys Q-Plex™ Human Micronutrient Array (7-Plex) are multiplex serum assays that are used to assess population micronutrient status in low-income countries. We aimed to compare the agreement of five analytes, α-1-acid glycoprotein (AGP), C-reactive protein (CRP), ferritin, retinol-binding protein 4 (RBP4) and soluble transferrin receptor (sTfR) as measured by the 7-Plex and the s-ELISA. Serum samples were collected between March 2016 and December 2017. Pregnant women (n 249) were recruited at primary healthcare clinics in Johannesburg, and serum samples were collected between March 2016 and December 2017. Agreement between continuous measurements was assessed by Bland-Altman plots and concordance measures. Agreement in classifications of deficiency or inflammation was assessed by Cohen's kappa. Strong correlations (r > 0·80) were observed between the 7-Plex and s-ELISA for CRP and ferritin. Except for CRP, the 7-Plex assay gave consistently higher measurements than the s-ELISA. With the exception of CRP (Lin's ρ = 0·92), there was poor agreement between the two assays, with Lin's ρ < 0·90. Discrepancies of test results difference between methods increased as the serum concentrations rose. Cohen's kappa for all the five analytes was < 0·81 and ranged from slight agreement (vitamin A deficiency) to substantial (inflammation and Fe deficiency) agreement. The 7-Plex 1.0 is a research and or surveillance tool with potential for use in low-resource laboratories but cannot be used interchangeably with the s-ELISA. Further optimising and validation is required to establish its interchangeability with other validated methods.

Keywords: C-reactive protein; Ferritin; Quansys 7-Plex assay; Retinol-binding protein; Soluble transferrin receptor; α-1-acid glycoprotein.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Anemia, Iron-Deficiency* / epidemiology
  • Biomarkers
  • C-Reactive Protein / metabolism
  • Female
  • Ferritins
  • Humans
  • Inflammation
  • Micronutrients
  • Pregnancy
  • Pregnant Women
  • Retinol-Binding Proteins, Plasma
  • South Africa
  • Trace Elements* / metabolism

Substances

  • Micronutrients
  • Ferritins
  • C-Reactive Protein
  • Trace Elements
  • Biomarkers
  • RBP4 protein, human
  • Retinol-Binding Proteins, Plasma