Local control and toxicity after magnetic resonance imaging (MR)-guided single fraction lung stereotactic ablative radiotherapy

Radiother Oncol. 2023 Oct:187:109823. doi: 10.1016/j.radonc.2023.109823. Epub 2023 Jul 27.

Abstract

Purpose: Magnetic resonance imaging (MR)-guided radiotherapy permits continuous intrafraction visualization and use of automatic triggered beam delivery, with use of smaller planning target volumes (PTV). We report on long-term clinical outcomes following MR-guided single fraction (SF) lung SABR on a 0.35 T linac.

Materials and methods: Details of patients treated with SF-SABR for lung tumors were accessed from an ethics approved institutional database. A breath-hold 3D MR simulation scan was performed using a true FISP sequence, followed by a breath-hold 3D CT scan. The gross tumor volume (GTV) was first contoured on the breath-hold CT scan, which was then compared with contours on the 3D MR scan, before the GTV was finalized. SABR plans used step-and-shoot IMRT beams to a PTV derived by adding a 5 mm margin to the breath-hold GTV, and a 3 mm gating window was used. SABR was delivered during repeated breath-holds, using automatic beam gating with continuous visualization of the GTV in a sagittal MR plane.

Results: Between 2018-2022, 50 consecutive patients were treated, and 69% had a primary non-small cell lung cancer. Median PTV was 11.2 cc (range 3.9-53.5); 80% of GTV's were located ≤2.5 cm from the chest wall. Prescribed doses were 34 Gy (in 58%), 30 Gy (32%), or between 20-28 Gy (10%). After a median follow-up of 18.1 months (95% CI 12.8-23.5), the 2-year survival was 82% (89% for primary NSCLC and 62% for metastases). After a median follow-up of 16.1 months (95% CI 11.2-21.1), local recurrences developed in 2 patients (4%). The 3-year local control rate was 97%, and just 1 patient developed grade ≥3 toxicity (chest wall pain).

Conclusion: MR-guided SF-SABR delivery to lung tumors on a 0.35 T linac, using repeated breath-holds with automatic beam gating, achieves good tumor control and low toxicity.

Keywords: Gated delivery; Lung cancer; MR-guided online adaptive SABR; Single fraction; Stereotactic ablative radiotherapy; Toxicity.

MeSH terms

  • Carcinoma, Non-Small-Cell Lung* / diagnostic imaging
  • Carcinoma, Non-Small-Cell Lung* / radiotherapy
  • Carcinoma, Non-Small-Cell Lung* / surgery
  • Etoposide
  • Humans
  • Lung / pathology
  • Lung Neoplasms* / diagnostic imaging
  • Lung Neoplasms* / pathology
  • Lung Neoplasms* / radiotherapy
  • Magnetic Resonance Imaging / methods
  • Radiosurgery* / adverse effects
  • Radiosurgery* / methods
  • Radiotherapy Planning, Computer-Assisted / methods
  • Retrospective Studies

Substances

  • Etoposide