Achieving bone fixation during megaprosthesis revision presents a formidable challenge in view of the substantial bone loss. We report treatment of a failed revision distal femoral replacement in an active 36-year-old male mechanic remotely treated for osteosarcoma. A custom stem and cone were manufactured to augment fixation and preserve bone stock within a short segment of the remaining proximal femur. The patient returned to regular function without the need for assistive devices. Follow-up imaging demonstrated stable implant fixation at 1-year follow-up. While cones and sleeves have vastly improved fixation in revision knee arthroplasty, a custom-made cone for the proximal femur was used to augment fixation of a revision megaprosthesis and obviate the use of a total femoral replacement.
Keywords: Aseptic loosening; Cone; Custom implant; Distal femur replacement; Megaprosthesis.