Validation of bone mineral density measurement using quantitative CBCT image based on deep learning

Sci Rep. 2023 Jul 24;13(1):11921. doi: 10.1038/s41598-023-38943-8.

Abstract

The bone mineral density (BMD) measurement is a direct method of estimating human bone mass for diagnosing osteoporosis, and performed to objectively evaluate bone quality before implant surgery in dental clinics. The objective of this study was to validate the accuracy and reliability of BMD measurements made using quantitative cone-beam CT (CBCT) image based on deep learning by applying the method to clinical data from actual patients. Datasets containing 7500 pairs of CT and CBCT axial slice images from 30 patients were used to train a previously developed deep-learning model (QCBCT-NET). We selected 36 volumes of interest in the CBCT images for each patient in the bone regions of potential implants sites on the maxilla and mandible. We compared the BMDs shown in the quantitative CBCT (QCBCT) images with those in the conventional CBCT (CAL_CBCT) images at the various bone sites of interest across the entire field of view (FOV) using the performance metrics of the MAE, RMSE, MAPE (mean absolute percentage error), R2 (coefficient of determination), and SEE (standard error of estimation). Compared with the ground truth (QCT) images, the accuracy of the BMD measurements from the QCBCT images showed an RMSE of 83.41 mg/cm3, MAE of 67.94 mg/cm3, and MAPE of 8.32% across all the bone sites of interest, whereas for the CAL_CBCT images, those values were 491.15 mg/cm3, 460.52 mg/cm3, and 54.29%, respectively. The linear regression between the QCBCT and QCT images showed a slope of 1.00 and a R2 of 0.85, whereas for the CAL_CBCT images, those values were 0.32 and 0.24, respectively. The overall SEE between the QCBCT images and QCT images was 81.06 mg/cm3, whereas the SEE for the CAL_CBCT images was 109.32 mg/cm3. The QCBCT images thus showed better accuracy, linearity, and uniformity than the CAL_CBCT images across the entire FOV. The BMD measurements from the quantitative CBCT images showed high accuracy, linearity, and uniformity regardless of the relative geometric positions of the bone in the potential implant site. When applied to actual patient CBCT images, the CBCT-based quantitative BMD measurement based on deep learning demonstrated high accuracy and reliability across the entire FOV.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Bone Density
  • Deep Learning*
  • Humans
  • Osteoporosis*
  • Reproducibility of Results
  • Spiral Cone-Beam Computed Tomography*