Computational modelling of the graft-tunnel interaction in single-bundle ACL reconstructed knee

Biomed Tech (Berl). 2023 Jul 19;68(6):573-582. doi: 10.1515/bmt-2022-0136. Print 2023 Dec 15.

Abstract

Objectives: Tunnel enlargement and graft failure are common complications associated with ACL reconstruction. The mechanical interaction between the graft and the tunnel aperture may play a more important role. This study aims to evaluate graft position within femoral tunnel and the graft force under external loads.

Methods: An FE model of the femur-graft-tibia complex was constructed from CT images of an anatomically reconstructed knee specimen. The model was subjected to kinematics of passive flexion extension, anterior/posterior translation, internal/external rotation and valgus kinematics, which were collected from experimental testing. Graft shift and rotation of graft-tunnel contact region during flexion/extension and external loadings were recorded and compared to experimental measurements.

Results: Model showed that the graft shifted in the femoral tunnel during flexion and under external loads. The graft-tunnel contact area rotated by up to 55° during flexion from full extension to 90° of extension implying that the so-called "wiper effect" occurs during most of flexion angles.

Conclusions: Different regions of the femoral tunnel aperture, particularly the anterior region, were under significantly more contact force from the graft than other areas of the aperture during the anterior translation test, potentially leading to femoral tunnel enlargement to the anterior side of the aperture.

Keywords: ACL graft; bone tunnel enlargement; finite element analysis; wind-shield wiper effect.

MeSH terms

  • Anterior Cruciate Ligament Reconstruction* / methods
  • Anterior Cruciate Ligament* / surgery
  • Biomechanical Phenomena
  • Cadaver
  • Computer Simulation
  • Femur / surgery
  • Humans
  • Knee Joint / surgery
  • Range of Motion, Articular