Radiation Source Localization Using a Model-Based Approach

Sensors (Basel). 2023 Jun 27;23(13):5983. doi: 10.3390/s23135983.

Abstract

The procedure is practically an optimization method, during which it is assumed that the gamma dose values detected at different points above the area come from the background radiation and from a single source found in the area. Accordingly, the procedure searches within the area for a geographical coordinate for which the distance law for the spatial propagation of radiation will be true. In order to validate the procedure, we performed measurements in a test area in such a way that all parameters of the source, including its location, were well defined. However, these data were not taken into account during the processing, i.e., the search procedure did not have these data. We can estimate the radiation position without a positional parameter. The exact coordinate and the intensity of the radiating sample were only used when checking the results. We have also applied the method to the raw data of our experiments carried out in the past if we used one source for them. The results confirmed our assumptions. The method is suitable for determining the starting parameters of more complex processes that can even detect multiple sources, but assuming one source, it has proven to be a reliable analytical method on its own.

Keywords: drone; field dose distribution; gamma radiation.

Grants and funding

This research received no external funding.