Shear wave velocity values measured by 2D-shear wave elastography are not different between awake and anesthetized cats without clinically significant hepatic fibrosis

Vet Radiol Ultrasound. 2023 Sep;64(5):913-919. doi: 10.1111/vru.13267. Epub 2023 Jul 13.

Abstract

Two-dimensional shear wave elastography (2D-SWE) is widely used as a noninvasive method to quantify liver stiffness. In humans, liver stiffness approximates histologic hepatic fibrosis. While histology is the gold standard for diagnosing liver disease, 2D-SWE may be a minimally invasive alternative to biopsy in feline patients. The objectives of this prospective, observational, crossover study were trifold: (1) to assess the feasibility of performing 2D-SWE in awake cats, (2) to determine whether anesthesia altered shear wave velocity (SWV) measurements, and (3) to correlate hepatic stiffness with histologically quantified hepatic fibrosis. Eleven healthy, purpose-bred cats underwent 2D-SWE in awake and anesthetized states. SWV measurements were compared with histologic fibrosis measurements obtained from liver biopsies during the anesthetic period. The mean velocities were not significantly different between awake (1.47 ± 0.18 m/s) and anesthetized (1.47 ± 0.24 m/s) cats. Premedication and anesthetic drugs did not impact mean SWV. There was a higher variability in the SWV values in the awake group. The data points were reliably replicated, with an interquartile range of 0.24 and 0.32 in anesthetized and awake groups, respectively. There was moderate agreement between observers (intraclass correlation coefficient = 0.66). All cats had clinically insignificant fibrosis. There was no correlation between the SWV measurements and the histological fibrosis values. This study demonstrates that 2D-SWE is feasible in awake cats and that the anesthetic protocol employed did not significantly alter mean SWV. This work is the first to histologically validate normal SWV values in cats and show that 2D-SWE cannot differentiate minimal differences in feline hepatic fibrosis.

Keywords: 2D-SWE; SWV; feline; fibrosis; liver disease; ultrasound; velocity.

Publication types

  • Observational Study

MeSH terms

  • Animals
  • Cat Diseases* / diagnostic imaging
  • Cat Diseases* / pathology
  • Cats
  • Cross-Over Studies
  • Elasticity Imaging Techniques* / methods
  • Elasticity Imaging Techniques* / veterinary
  • Humans
  • Liver / diagnostic imaging
  • Liver / pathology
  • Liver Cirrhosis / diagnostic imaging
  • Liver Cirrhosis / veterinary
  • Prospective Studies
  • Wakefulness