Disinfection and Shaping of Vertucci Class II Root Canals after Preparation with Two Instrument Systems and Supplementary Ultrasonic Activation of Sodium Hypochlorite

J Endod. 2023 Sep;49(9):1183-1190. doi: 10.1016/j.joen.2023.06.017. Epub 2023 Jul 6.

Abstract

Introduction: This study compared disinfection and shaping after root canal preparation with either XP-endo Shaper or TruNatomy instrument systems, supplemented by ultrasonic activation of sodium hypochlorite (NaOCl) with either stainless-steel (SS) or nickel-titanium (NiTi) inserts.

Methods: Mesial roots from mandibular molars with Vertucci class II configuration were divided into 2 groups (n = 24) based on anatomically paired micro-computed tomography (micro-CT) analyses. Pre and postpreparation micro-CT scans were obtained to evaluate the shaping performance. The canals were contaminated with a mixed bacterial culture for 30 days and then subjected to preparation with either XP-endo Shaper or TruNatomy instruments using NaOCl irrigation. Supplementary ultrasonic activation of NaOCl was conducted using either an SS (TruNatomy group) or NiTi (XP-endo Shaper group) insert. Bacteriological samples were taken from the canals before preparation (S1), after preparation (S2), and after the supplementary approach (S3). Bacterial reduction was evaluated using a quantitative real-time polymerase chain reaction.

Results: Preparation with both instrument systems significantly reduced bacterial counts (P < .01). After preparation, 36% (TruNatomy) and 35% (XP-endo Shaper) were negative for bacteria. These values increased to 59% and 65% after ultrasonic activation with the SS and NiTi inserts, respectively. The quantitative data in S2 showed that XP-endo Shaper promoted a significantly higher bacterial reduction than TruNatomy (P < .05). No significant intragroup differences were observed after ultrasonic activation (P > .05), probably because the SS insert promoted a significantly higher S2-to-S3 reduction than the NiTi insert (P < .01). Micro-CT analysis revealed no significant differences in the unprepared areas between the groups (P > .05).

Conclusions: The XP-endo Shaper caused a significantly higher bacterial reduction than TruNatomy in Vertucci class II canals. Better antibacterial results after ultrasonic activation were observed for the SS ultrasonic inserts than for the NiTi inserts.

Keywords: Bacterial reduction; endodontic treatment; root canal preparation; sodium hypochlorite; ultrasonics; unprepared canal surface.

MeSH terms

  • Dental Pulp Cavity* / diagnostic imaging
  • Dental Pulp Cavity* / microbiology
  • Disinfection
  • Root Canal Preparation
  • Sodium Hypochlorite* / therapeutic use
  • Ultrasonics
  • X-Ray Microtomography

Substances

  • Sodium Hypochlorite
  • titanium nickelide