The stability of C-peptide and insulin in plasma and serum samples under different storage conditions

Clin Chem Lab Med. 2023 Jul 7;61(12):2150-2158. doi: 10.1515/cclm-2023-0339. Print 2023 Nov 27.

Abstract

Objectives: C-peptide and insulin are peptide hormones and their stability is affected by a number of pre-analytical factors. The study aimed to investigate the impact of sample type, storage temperature and time delays before centrifugation and analysis on the stability of C-peptide and insulin.

Methods: Ten healthy non-diabetic adults in fasting and non-fasting state were enrolled. 40 mL of blood was collected from each participant into SST and dipotassium EDTA tubes. Samples were centrifuged immediately or at timed intervals (8, 12, 48 and 72 h). After baseline measurements on the Roche Cobas e602 analyzer using electrochemiluminescence immunoassays, aliquots were stored at room temperature (RT), 2-8 and -20 °C for 4 h to 30 days. The percentage deviation (PD) from baseline was calculated and a change greater than desirable biological variation total error was considered clinically significant.

Results: C-peptide was more stable in separated serum than plasma (PD of -5 vs. -13 %) samples stored at 2-8 °C for 7 days and was most unstable at RT when centrifugation was delayed (PD -46 % in plasma and -74 % in serum after 48 h). Insulin was more stable in plasma than in serum under the different storage conditions with a minimum PD of -1% when stored at -20 °C for 30 days. When samples were kept unspun at RT for 72 h, PD was -23 and -80 % in plasma and serum, respectively.

Conclusions: C-peptide was more stable in serum provided the sample was centrifuged immediately and stored in the fridge or freezer while insulin was found to be more stable in EDTA plasma.

Keywords: C-peptide; insulin; sample stability.

MeSH terms

  • Adult
  • Blood Specimen Collection
  • C-Peptide
  • Edetic Acid
  • Humans
  • Insulin*
  • Plasma*
  • Serum
  • Temperature

Substances

  • Insulin
  • C-Peptide
  • Edetic Acid