Evaluation of Sedation Levels Using SedLine During Intravenous Sedation for Dental Procedures: A Case-Series Study

Anesth Prog. 2023 Jun 1;70(2):85-87. doi: 10.2344/anpr-70-01-01.

Abstract

The Patient State Index (PSI) is the numerical value of anesthesia depth as measured using a SedLine Sedation Monitor (Masimo Corporation). In this pilot study, we evaluated PSI values captured during intravenous (IV) moderate sedation for dental treatment. During the dental treatment, a dental anesthesiologist maintained the Modified Observer's Assessment of Alertness/Sedation (MOAA/S) score at 3 to 4 by adjusting the administration of midazolam and propofol while PSI values were recorded. The mean (SD) and median (25th percentile, 75th percentile) PSI values during dental treatment under IV moderate sedation were 72.7 (13.6) and 75 (65, 85), respectively.

Keywords: Intravenous sedation; Moderate sedation; Patient State Index (PSI); SedLine.

MeSH terms

  • Anesthesia, Dental*
  • Conscious Sedation
  • Humans
  • Hypnotics and Sedatives
  • Midazolam
  • Pilot Projects
  • Propofol*

Substances

  • Propofol
  • Midazolam
  • Hypnotics and Sedatives