Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant-supported full arch fixed prosthesis

J Esthet Restor Dent. 2023 Dec;35(8):1257-1263. doi: 10.1111/jerd.13070. Epub 2023 Jun 13.

Abstract

Objective: This study evaluated the accuracy of different intraoral scanners (IOS) for scanning of implant-supported full arch fixed prosthesis with different implant angulations with and without scanbodies splinting.

Materials and methods: Two maxillary models were designed and fabricated to receive an all-on-four implant retained. The models were divided into two groups according to the angulation of the posterior implant (Group 1; 30 and Group 2; 45). Each group was then divided into three subgroups according to the type of IOS used: Subgroup C; Primescan, subgroup T; Trios4, and subgroup M; Medit i600. Then each subgroup was divided into two divisions according to scanning technique; division S: splinted and division N: nonsplinted. Ten scans were made by each scanner for every division. Trueness and precision were analyzed using Geomagic controlX analysis software.

Results: Angulation had no significant effect on both the trueness (p = 0.854) and precision (p = 0.347). Splinting had a significant effect on trueness and precision (p < 0.001). Scanner type had a significant effect on trueness (p < 0.001) and precision (p < 0.001). There was no significant difference between trueness of Trios 4 (112.15 ± 12.85) and Primescan (106.75 ± 22.58). However, there was a significant difference when compared to trueness of Medit i600 (158.50 ± 27.65). For the precision results Cerec Primescan showed the highest precision (95.45 ± 33.21). There was a significant difference between the three scanners, precision of Trios4 (109.72 ± 19.24) and Medit i600 (121.21 ± 17.26).

Conclusion: Cerec Primescan has higher trueness and precision than Trios 4 and Medit i600 in full arch implants scanning. Splinting the scanbodies improve the accuracy of full arch implants scanning.

Clinical significance: Cerec Primescan and 3Shape Trios 4 can be used for scanning of All-on-four implant supported prosthesis when scanbodies are splinted using a modular chain device.

Keywords: all-on-4; dental implants; digital dentistry; fixed prosthodontics; implant scanbody.

MeSH terms

  • Computer-Aided Design
  • Dental Arch
  • Dental Implants*
  • Dental Impression Technique
  • Imaging, Three-Dimensional*
  • Models, Dental

Substances

  • Dental Implants