Advanced electrochemical potential monitoring for improved understanding of electrical neurostimulation protocols

J Neural Eng. 2023 Jun 22;20(3). doi: 10.1088/1741-2552/acdd9d.

Abstract

Objective.Current-controlled neurostimulation is increasingly used in the clinical treatment of neurological disorders and widely applied in neural prostheses such as cochlear implants. Despite its importance, time-dependent potential traces of electrodes during microsecond-scale current pulses, especially with respect to a reference electrode (RE), are not precisely understood. However, this knowledge is critical to predict contributions of chemical reactions at the electrodes, and ultimately electrode stability, biocompatibility, and stimulation safety and efficacy.Approach.We assessed the electrochemistry of neurostimulation protocolsin vitrowith Pt microelectrodes from millisecond (classical electroanalysis) to microsecond (neurostimulation) timescales. We developed a dual-channel instrumentation amplifier to include a RE in neurostimulation setups. Uniquely, we combined potential measurements with potentiostatic prepolarization to control and investigate the surface status, which is not possible in typical stimulation setups.Main results.We thoroughly validated the instrumentation and highlighted the importance of monitoring individual electrochemical electrode potentials in different configurations of neurostimulation. We investigated electrode processes such as oxide formation and oxygen reduction by chronopotentiometry, bridging the gap between milli- and microsecond timescales. Our results demonstrate how much impact on potential traces the electrode's initial surface state and electrochemical surface processes have, even on a microsecond scale.Significance.Our unique use of preconditioning in combination with stimulation reveals that interpreting potential traces with respect to electrode processes is misleading without rigorous control of the electrode's surface state. Especiallyin vivo, where the microenvironment is unknown, simply measuring the voltage between two electrodes cannot accurately reflect the electrode's state and processes. Potential boundaries determine charge transfer, corrosion, and alterations of the electrode/tissue interface such as pH and oxygenation, particularly in long-termin vivouse. Our findings are relevant for all use-cases of constant-current stimulation, strongly advocating for electrochemicalin situinvestigations in many applications like the development of new electrode materials and stimulation methods.

Keywords: chronopotentiometry; electrochemistry; electrode potential; neurostimulation; platinum; potentiostat.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cochlear Implantation*
  • Cochlear Implants*
  • Electrochemistry / methods
  • Electrodes
  • Microelectrodes
  • Neural Prostheses*
  • Platinum

Substances

  • Platinum