Application of titanium 3D-printed double-sleeve guide for zygomatic implants: A technique report

J Prosthodont. 2023 Oct;32(8):752-756. doi: 10.1111/jopr.13724. Epub 2023 Jun 22.

Abstract

The unique anatomical structure of the atrophic edentulous maxilla limits the placement of endosteal root form dental implants without bone grafting and augmentation. Surgical placement of zygomatic implants in an optimal position remains challenging. This technique report illustrates a novel digital guide technology, including the design workflow, application method, and indications for assisting with the placement of zygomatic implants using a bone-supported titanium double-sleeve guide. In addition, when the implant body reaches the zygomatic bone following an intra-sinus path, including ZAGA type 0 and ZAGA type 1 cases, a matching window osteotomy surgical guide is used to locate the lateral window boundary and protect the sinus membrane. With this technique, the surgical procedure is simplified, and the precision of guided zygomatic implant placement is improved.

Keywords: double-sleeve guide; sinus window osteotomy guide; titanium 3D-printed guide; zygomatic implants.

MeSH terms

  • Bone Transplantation
  • Dental Implantation, Endosseous / methods
  • Dental Implants*
  • Dental Prosthesis, Implant-Supported
  • Humans
  • Jaw, Edentulous* / surgery
  • Maxilla / surgery
  • Printing, Three-Dimensional
  • Titanium
  • Zygoma / surgery

Substances

  • Dental Implants
  • Titanium