The effects of lead equivalent and lens area of radiation-protective eyewear on lens exposure control were examined. The simulated patient underwent 10-min X-ray fluoroscopy, and the lens dose of the simulated surgeon wearing radiation protection glasses was measured using lens dosemeters attached to the corner of the eye and eyeball. In total, 10 types of radiation protection glasses were selected for measurement. Correlation analysis of the equivalent dose in the lens of the eye with lead equivalence and lens area was performed. The equivalent dose in the lens of the eye of the corner of the eye was negatively correlated with the area of the lens. The equivalent dose in the lens of the eye and the eyeball showed a strong negative correlation with lead equivalence. Lens dosemeters worn at the corner of the eye may overestimate the equivalent dose in the lens of the eye. Moreover, the reduction in exposure of the lens was significantly influenced by the lead equivalent.