Computational fluid-particle dynamics modeling of ultrafine to coarse particles deposition in the human respiratory system, down to the terminal bronchiole

Comput Methods Programs Biomed. 2023 Jul:237:107589. doi: 10.1016/j.cmpb.2023.107589. Epub 2023 May 6.

Abstract

Background and objectives: Suspended respirable airborne particles are associated with human health risks and especially particles within the range of ultrafine (< 0.1 μm) or fine (< 2.5 μm) have a high possibility of penetrating the lung region, which is concerned to be closely related to the bronchial or alveoli tissue dosimetry. Nature complex structure of the respiratory system requires much effort to explore and comprehend the flow and the inhaled particle dynamics for precise health risk assessment. Therefore, this study applied the computational fluid-particle dynamics (CFPD) method to elucidate the deposition characteristics of ultrafine-to-coarse particles in the human respiratory tract from nostrils to the 16th generation of terminal bronchi.

Methods: The realistic bronchi up to the 8th generation are precisely and perfectly generated from computed tomography (CT) images, and an artificial model compensates for the 9th-16th bronchioles. Herein, the steady airflow is simulated at constant breathing flow rates of 7.5, 15, and 30 L/min, reproducing human resting-intense activity. Then, trajectories of the particle size ranging from 0.002 - 10 μm are tracked using a discrete phase model.

Results: Here, we report reliable results of airflow patterns and particle deposition efficiency in the human respiratory system validated against experimental data. The individual-related focal point of ultrafine and fine particles deposition rates was actualized at the 8th generation; whilst the hot-spot of the deposited coarse particles was found in the 6th generation. Lobar deposition characterizes the dominance of coarse particles deposited in the right lower lobe, whereas the left upper-lower and right lower lobes simultaneously occupy high deposition rates for ultrafine particles. Finally, the results indicate a higher deposition in the right lung compared to its counterpart.

Conclusions: From the results, the developed realistic human respiratory system down to the terminal bronchiole in this study, in coupling with the CFPD method, delivers the accurate prediction of a wide range of particles in terms of particle dosimetry and visualization of site-specific in the consecutive respiratory system. In addition, the series of CFPD analyses and their results are to offer in-depth information on particle behavior in human bronchioles, which may benefit health risk assessment or drug delivery studies.

Keywords: Computational fluid-particle dynamics; Human respiratory tract; Particle deposition; Tracheobronchial airway; Ultrafine-to-coarse particles.