"Wearable Sensors to Guide Remote Rehabilitation Following Knee Arthroplasty Surgery"

Indian J Orthop. 2022 Dec 12;57(5):624-634. doi: 10.1007/s43465-022-00785-3. eCollection 2023 May.

Abstract

Background: Total knee arthroplasty requires effective rehabilitation to achieve optimal results, but institutions often rely on unsupervised home exercises due to cost constraints. Wearable sensors have become increasingly popular as a potential method of monitoring patients remotely to ensure efficacy and compliance. This review assesses the current evidence for their use in remotely monitored rehabilitation following knee arthroplasty.

Methods: A systematic review of the literature from 1st January 2000 to 17th February 2022 was undertaken. Devices were categorised as joint-specific or physical activity sensors. Studies were classified as those providing remotely supervised rehabilitation as an additional or as an alternative intervention.

Results: Remotely supervised rehabilitation using wearable sensors demonstrated similar outcomes when provided as an alternative to standard care in most studies. One group found improved outcomes for knee-specific sensors compared with standard care. There were improved physical activity and healthcare resource use outcomes described in the literature where sensors were used in addition to standard care.

Discussion: This review found evidence for the use of wearable sensors in remotely supervised rehabilitation following knee arthroplasty surgery. This included methodological heterogeneity, differing definitions of standard care, and variable follow-up periods. Robust randomised control trial data with a longer follow-up period are needed.

Keywords: Knee arthroplasty; Knee replacement; Remote rehabilitation; Telerehabilitation; Wearable sensors.

Publication types

  • Review