A new method for measuring penile curvature based on digital images

J Pediatr Urol. 2023 Aug;19(4):396.e1-396.e6. doi: 10.1016/j.jpurol.2023.04.001. Epub 2023 Apr 6.

Abstract

Introduction and objective: Accurate and objective assessment of penile curvature is considered a critical evaluation in patients with hypospadias, as it often determines if a 1 or 2-stage procedure should be done. Due to the ease of acquisition and reusability of digital images, more research is focused on digital images; however, the current method based on digital images is not an easily accurate and objective evaluation of penile curvature amongst surgeons. In scoliosis, the Cobb method is a standard method to quantify spinal curvature. Therefore, this study introduces a new accurate, and standardized method for measuring penile curvature based on the digital image concerning the Cobb method.

Methods: Twenty-two subjects were randomly selected, including 11 pediatric urologists with experience in goniometry(professional group)and 11 non-pediatric urologists without experience in goniometry (non-professional group). A total of 9 two-dimensional images of penile curvatures from 10° to 90°were obtained and stored in the research project notebook. Subjects measured 9 digital images using the new method (fixed anatomical position method) and classical method (the angle created by the interception of two ideal lines, one passing along the proximal portion of the corpora and a second passing through the tip of the penis), respectively. Measurement error was calculated as the absolute difference between the true curvature and the subject estimation. A t-test was used to evaluate the significant differences between the methods.

Results: A total of 22 subject measurement data were obtained. Mean errors using the new method ranged from 1.06° to 3.50°, compared to 3.84°to 11.83°for classical method. Mean errors were significantly lower (p < 0.05) when using the new method compared to the classical method. A subgroup comparing subjects with and without prior experience with goniometry showed a statistically significant difference only for the classical method when the penis curvature is 10-40°, the mean error range of the professional group was 7.8°-9.56°, compared to 10.34°-13.02°for nonprofessional group.

Discussion: We emphasize the importance of penile curvature measurement and urgent need for an accurate measurement method, and then we focus on the new method compare with the previously described methods looking at mean errors and explain the reason that the new method why is accurate. Subsequently, we focus on explain the impact of experience measurement methods. Finally, the shortcomings of this paper and the prospective points are discussed:1) how to obtain more photos in practical situations; 2) using artificial intelligence methods for automatic marking of key points to achieve efficient measurement of penile curvature.

Conclusions: In this preliminary study, we demonstrated better penile curvature estimations using the new method compared to the classical methods currently used by pediatric urologists.

Keywords: Chordee; Digital images; Penile curvature.