A Tool to Assess Competence in Critical Care Ultrasound Based on Entrustable Professional Activities

ATS Sch. 2023 Jan 24;4(1):61-75. doi: 10.34197/ats-scholar.2022-0063OC. eCollection 2023 Mar.

Abstract

Background: Existing assessment tools for competence in critical care ultrasound (CCUS) have limited scope and interrupt clinical workflow. The framework of entrustable professional activities (EPAs) is well suited to developing an assessment tool that is comprehensive and readily integrated into the intensive care unit (ICU) training environment.

Objective: This study sought to design an EPA-based tool to assess competence in CCUS for pulmonary and critical care fellows and to assess the validity and reliability of the tool.

Methods: Eight experts in CCUS met to define the core EPAs for CCUS. A nominal group technique was used to reach consensus. An assessment tool was created based on the EPAs with a modified Ottawa entrustability scale. Trained faculty evaluated pulmonary and critical care fellows using this tool in the ICU over a 6-month study period at a single institution. An assessment of validity of the EPA-based tool is made with four sources of validity evidence: content, response process, reliability, and relation to other variables. Reliability and response process data were generated using generalizability theory analysis to estimate sources of variance in entrustment scores. Analysis of response process validity and validity by relation to other variables was performed using regression models.

Results: Fifty-four assessments were recorded during the study period, conducted on 23 trainees by 13 faculty. Content validity of the tool was demonstrated using expert consensus and published guidelines from critical care societies to define the EPAs. Response process validity was demonstrated by the low variance in entrustment scores due to evaluators (0.086 or 6%) and high agreement between score and trainee self-assessment (regression coefficient, 0.82; P < 0.0001). Reliability was demonstrated by the high "true" variance in entrustment score attributable to the trainee: 0.674 or 45%. Validity by relation to other variables was demonstrated using regression analysis to show correlation between entrustment score and the number of times a fellow has performed an EPA (regression coefficient, 0.023; P < 0.0001).

Conclusion: An EPA-based assessment tool for competence in CCUS was created. We obtained sufficient validity evidence on three of the diagnostic EPAs. Procedural EPAs were infrequently assessed, limiting generalizability in this subgroup.

Keywords: assessment; critical care; intensive care unit; point-of-care ultrasound; validity.