Outcomes of Ceramic-On-Ceramic Bearing Total Hip Arthroplasty: A Minimum 10-Year Follow-Up Study

J Arthroplasty. 2023 Jul;38(7S):S146-S151. doi: 10.1016/j.arth.2023.04.018. Epub 2023 Apr 19.

Abstract

Background: Although the fourth generation of ceramics has demonstrated excellent clinical results 5 to 6 years postoperatively, concerns over ceramic fracture and squeaking persist and longer-term follow-up (minimum 10 years) studies are warranted. Our study aimed to evaluate the minimum 10-year clinical outcomes and bearing-specific complications of ceramic-on-ceramic (CoC) total hip arthroplasties.

Methods: We retrospectively evaluated all patients who underwent primary delta CoC total hip arthroplasty in our institution between January 2004 and February 2013. Demographics, surgical techniques, complications, patient-reported outcomes, and radiographic outcomes were collected and analyzed. For continuous variables, the comparison between groups was conducted using a one-way analysis of variance. Of all 235 patients included in the study, 70.5% were women (190 hips). The mean follow-up period was 12 years (range, 10 to 18). The femoral head sizes of 28- mm, 32 mm, and 36 mm were used in 50, 26, and 197 cases, respectively. Mean acetabular inclination and anteversion angles were 39.2 ± 7.1° and 14.9 ± 3.5°.

Results: There were 5 hips revised at a mean 4.6 years (range, 0.1 to 7.1). One revision was squeaking-related. Squeaking was also reported by 8 other patients, but did not require revision. Other reasons for revision were early infection in 2 cases, stem loosening in 1 case, and stem fracture in 2 cases. The survival analysis for any causes for revision as an endpoint was 96.7% (95% confidence interval 0.313%-2.57%).

Conclusion: We report excellent mean 12-year follow-up results regarding the complications and survivorship of the fourth generation CoC bearings.

Keywords: BIOLOX delta; ceramic composite hip prosthesis; ceramic-on-ceramic; fourth generation of ceramics; hip squeaking; total hip arthroplasty.

MeSH terms

  • Arthroplasty, Replacement, Hip* / methods
  • Ceramics
  • Female
  • Follow-Up Studies
  • Fractures, Bone* / surgery
  • Hip Joint / diagnostic imaging
  • Hip Joint / surgery
  • Hip Prosthesis*
  • Humans
  • Male
  • Prosthesis Design
  • Prosthesis Failure
  • Retrospective Studies
  • Treatment Outcome