Impact of Cataract Surgery on IOP and Ocular Structures in Normotensive Patients and Primary and Exfoliation Open-Angle Glaucoma Patients

Clin Ophthalmol. 2023 Apr 5:17:1047-1055. doi: 10.2147/OPTH.S402550. eCollection 2023.

Abstract

Purpose: The aim of this study was to evaluate and compare the changes in Intraocular Pressure (IOP) and other ocular parameters: the Anterior Chamber Angle (ACA), Anterior Chamber Volume (ACV), and Anterior Chamber Depth (ACD) during phacoemulsification surgery in Greek patients with normotensive eyes and those with well-controlled Open-Angle Glaucoma (OAG). Additionally, parameters such as the Corneal Thickness (CCT), Axial Length (AL), Central Macular Thickness (CMT), and Retinal Nerve Fibre Layer (RNFL) were also examined.

Patients and methods: This was a prospective observational case-control study that included 50 phakic eyes, 25 normotensive (Group 1), and 25 with OAG: 15 Primary Open-Angle Glaucoma (POAG) and 10 Exfoliation Glaucoma (EXG) (Group 2). Ophthalmic assessment included IOP measurements, ocular biometry, and anterior and posterior segment optical coherence tomography evaluation of the aforementioned ocular parameters, prior and 6 months after phacoemulsification surgery.

Results: At the 6 months post-operative review, a greater IOP reduction was recorded in eyes with OAG, in comparison to normotensive ones (5.3mmHg and 1.6 mmHg respectively). In addition, a significant but similar increase was recorded in the values of the ACA, ACV, and ACD of both groups between the pre- and the post-op period. Furthermore, the CCT and AL values remained unaltered. Finally, there was a non-statistically significant change in the mean CMT and the mean average RNFL of both groups.

Conclusion: Eyes with OAG tend to undergo a greater reduction in IOP post-phacoemulsification surgery, in comparison to normotensive eyes. This reduction may not be solely attributed to ocular anatomical changes after phacoemulsification surgery but may also be due to the remodeling of the trabecular meshwork and the ciliary body. This may be especially true in the case of OAG eyes, which already start off with a compromised trabecular endothelium prior to surgery.

Keywords: axial length; biometry; cataract surgery; corneal pachymetry; intraocular pressure; open angle glaucoma.

Grants and funding

The authors received no financial support for the research, authorship, and publication of this article.