Background: To explore the efficacy and safety of laser peripheral iridoplasty (LPIp) with different energy levels and locations in the treatment of primary angle closure disease (PACD) assessed by swept-source anterior segment optical coherence tomography (AS-OCT).

Methods: We enrolled patients with PACD following best-corrected visual acuity (BCVA), intraocular pressure (IOP), anterior chamber gonioscopy, ultrasound biomicroscopy(UBM), optic disc OCT, and visual field examinations. After Pentacam and AS-OCT measurements, the patients were randomly divided into four treatment groups for LPIp with two different energy levels (high vs. low energy) and two locations (far from the periphery vs. near the periphery) and combined with laser peripheral iridotomy. BCVA, IOP, pupil diameter, central anterior chamber depth, anterior chamber volume, anterior opening distance (AOD)500, AOD750, trabecular iris angle (TIA)500, and TIA750 in four quadrants before and after laser treatment were compared.

Results: We followed up 32 patients (64 eyes; average age, 61.80 ± 9.79 years; 8 patients/16 eyes per group) for up to 2 years. The IOP of all enrolled patients was decreased after surgery compared to that before (t = 3.297, P = 0.002), the volume of the anterior chamber was increased (t=-2.047, P = 0.047), and AOD500, AOD750, TIA500, and TIA750 were increased (all P < 0.05). Within-group comparisons showed that BCVA in the low-energy/far-periphery group was improved after surgery (P < 0.05). After surgery, the IOP was decreased in the two high-energy groups, whereas the volume of the anterior chamber, AOD500, AOD750, TIA500, and TIA750 were increased in all groups (all P < 0.05). However, when comparing every two groups, the high-energy/far-periphery group showed a stronger effect on pupil dilation than the low-energy/near-periphery group (P = 0.045). The anterior chamber volume in the high-energy/near-periphery group was larger than that in the high-energy/far-periphery group (P = 0.038). The change in TIA500 was for 6 points smaller in the low-energy/near-periphery group than in the low-energy/far-periphery group (P = 0.038). Other parameters showed no significant group differences.

Conclusion: LPIp combined with iridotomy can effectively reduce IOP, increase anterior chamber volume, increase chamber angle opening distance, and widen the trabecular iris angle. Intraoperatively, high-energy laser spots positioned one spot diameter from the scleral spur can obtain the best effect and safety. Swept-source AS-OCT can safely and effectively quantify the anterior chamber angle.

Keywords: Efficacy; Laser energy; Laser location; Laser peripheral iridoplasty; Safety; Swept-source AS-OCT.