An axisymmetric mirror device for studying confinement and instability

Rev Sci Instrum. 2023 Mar 1;94(3):033507. doi: 10.1063/5.0117894.

Abstract

We describe a magnetic mirror device, namely, the Keda Mirror with AXisymmetricity (KMAX), which aims to study new approaches to confine and stabilize the mirror plasma as well as basic plasma research. KMAX consists of one central cell, two side cells, and two end chambers at two ends of the device. For the central cell, the mirror-to-mirror distance is 5.2 m, while the central cylinder is 2.5 m in length and 1.2 m in diameter. The plasmas are generated by two washer guns located in the end chambers, which subsequently flow into the central cell and merge there. The density in the central cell is usually adjusted by changing the magnetic field strength inside the side cell, and it ranges from 1017 to 1019 m-3, depending on the experimental requirement. Ion cyclotron frequency heating with two 100 kW transmitters is routinely used to heat up the ions. Plasma controls mainly rely on configuring the magnetic geometry and rotating magnetic fields to improve the confinement and suppress instability. Routine diagnostics, such as probes, interferometers, spectrometers, diamagnetic loops, and bolometers, are also reported in this paper.