Supply and quality of colonoscopy according to the characteristics of gastroenterologists in the French population-based colorectal-cancer screening program

World J Gastroenterol. 2023 Mar 7;29(9):1492-1508. doi: 10.3748/wjg.v29.i9.1492.

Abstract

Background: Since its complete roll-out in 2009, the French colorectal cancer screening program (CRCSP) experienced 3 major constraints [use of a less efficient Guaiac-test (gFOBT), stopping the supply of Fecal-Immunochemical-Test kits (FIT), and suspension of the program due to the coronavirus disease 2019 (COVID-19)] affecting its effectiveness.

Aim: To describe the impact of the constraints in terms of changes in the quality of screening-colonoscopy (Quali-Colo).

Methods: This retrospective cohort study included screening-colonoscopies performed by gastroenterologists between Jan-2010 and Dec-2020 in people aged 50-74 living in Ile-de-France (France). The changes in Quali-colo (Proportion of colonoscopies performed beyond 7 mo (Colo_7 mo), Frequency of serious adverse events (SAE) and Colonoscopy detection rate) were described in a cohort of Gastroenterologists who performed at least one colonoscopy over each of the four periods defined according to the chronology of the constraints [gFOBT: Normal progress of the CRCSP using gFOBT (2010-2014); FIT: Normal progress of the CRCSP using FIT (2015-2018); STOP-FIT: Year (2019) during which the CRCSP experienced the cessation of the supply of test kits; COVID: Program suspension due to the COVID-19 health crisis (2020)]. The link between each dependent variable (Colo_7 mo; SAE occurrence, neoplasm detection rate) and the predictive factors was analyzed in a two-level multivariate hierarchical model.

Results: The 533 gastroenterologists (cohort) achieved 21509 screening colonoscopies over gFOBT period, 38352 over FIT, 7342 over STOP-FIT and 7995 over COVID period. The frequency of SAE did not change between periods (gFOBT: 0.3%; FIT: 0.3%; STOP-FIT: 0.3%; and COVID: 0.2%; P = 0.10). The risk of Colo_7 mo doubled between FIT [adjusted odds ratio (aOR): 1.2 (1.1; 1.2)] and STOP-FIT [aOR: 2.4 (2.1; 2.6)]; then, decreased by 40% between STOP-FIT and COVID [aOR: 2.0 (1.8; 2.2)]. Regardless of the period, this Colo_7 mo's risk was twice as high for screening colonoscopy performed in a public hospital [aOR: 2.1 (1.3; 3.6)] compared to screening-colonoscopy performed in a private clinic. The neoplasm detection, which increased by 60% between gFOBT and FIT [aOR: 1.6 (1.5; 1.7)], decreased by 40% between FIT and COVID [aOR: 1.1 (1.0; 1.3)].

Conclusion: The constraints likely affected the time-to-colonoscopy as well as the colonoscopy detection rate without impacting the SAE's occurrence, highlighting the need for a respectable reference time-to-colonoscopy in CRCSP.

Keywords: Colorectal cancer screening; Faecal immunochemical test; Guaiac faecal occult blood test; Quality of colonoscopy; Screening colonoscopy; Severity of tumor lesions.

MeSH terms

  • COVID-19* / diagnosis
  • COVID-19* / epidemiology
  • Colonoscopy
  • Colorectal Neoplasms* / diagnosis
  • Colorectal Neoplasms* / epidemiology
  • Early Detection of Cancer
  • Gastroenterologists*
  • Guaiac
  • Humans
  • Mass Screening
  • Occult Blood
  • Radiopharmaceuticals
  • Retrospective Studies

Substances

  • Guaiac
  • Radiopharmaceuticals