Clinical outcomes of handmade polytetrafluoroethylene trileaflet-valved conduit used for pulmonary valve replacement

Eur J Cardiothorac Surg. 2023 Jun 1;63(6):ezad120. doi: 10.1093/ejcts/ezad120.

Abstract

Objectives: To mitigate the shortage of homograft sources, the use of handmade trileaflet expanded polytetrafluoroethylene valves in pulmonary valve replacement has shown excellent results from multicentre studies conducted in Japan. However, world-wide data outside Japan are relatively insufficient. This study presents the long-term results of a single surgeon's use of flipped-back trileaflet method in a 10-year case series.

Methods: We have developed an efficient way to make a trileaflet-valved conduit utilizing flipped-back method for pulmonary valve replacement and have employed the technique since 2011. Retrospective data were studied between October 2010 and January 2020. Echocardiography, electrocardiogram, Pro-Brain Natriuretic Peptide and Magnetic Resonance Imaging data were analysed.

Results: Fifty-five patients were reviewed and median follow-up duration was 2.9 years. The majority of diagnoses was Tetralogy of Fallot (n = 41), and these patients subsequently underwent secondary pulmonary valve replacement at a median age of 15.6 years. Survival was 92.7% with the longest follow-up period being 10 years. There was no need for reoperation, and freedom from reintervention was 98.0% at 10 years. There were 4 deaths (3 in-hospital and 1 outpatient). One patient eventually received transcatheter pulmonary valve implantation. Postoperative echocardiography showed mild or less pulmonary stenosis and pulmonary regurgitation degree in 92.2% and 92.0% of patients, respectively. Comparable magnetic resonance imaging data (n = 25) showed significant reduction in right ventricular volumes but not in ejection fractions.

Conclusions: Our series showed satisfactory long-term function of handmade flipped-back trileaflet-valved conduit used in our patients. The simple design is efficiently reproducible without complex fabrication process.

Keywords: Polytetrafluoroethylene valve; Pulmonary valve replacement; Right ventricular outflow tract reconstruction; Tetralogy of Fallot.

MeSH terms

  • Adolescent
  • Heart Valve Prosthesis Implantation*
  • Heart Valve Prosthesis*
  • Humans
  • Polytetrafluoroethylene
  • Prosthesis Design
  • Pulmonary Valve* / surgery
  • Retrospective Studies
  • Treatment Outcome
  • Ventricular Outflow Obstruction* / surgery

Substances

  • Polytetrafluoroethylene